登录 EN

添加临时用户

基于等离子体射流处理的风电叶片表面修复技术研究

Research on Surface Repair Technology of Wind Turbine Blade Based on Plasma Jet Treatment

作者:杨紫贝
  • 学号
    2022******
  • 学位
    硕士
  • 电子邮箱
    187******com
  • 答辩日期
    2025.05.18
  • 导师
    王希林
  • 学科名
    电气工程
  • 页码
    85
  • 保密级别
    公开
  • 培养单位
    599 国际研究生院
  • 中文关键词
    叶片修复;等离子体射流;附着强度
  • 英文关键词
    wind turbine blade repair; plasma jet; adhesion strength.

摘要

广东沿海风电叶片在长期恶劣服役环境下表面易损坏,严重影响其可靠性和使用寿命,传统修复方法获得的涂层与叶片基体结合性能差。本文提出基于大气压氩等离子体射流的表面改性技术,研究改性机理并优化处理参数,系统评估了等离子体射流对玻璃纤维增强复合材料(GFRP)基体与修复涂层间界面结合性能的影响,并探索风电叶片修复新方法。通过大气压氩等离子体射流表面处理实现GFRP基体与修复树脂涂层界面结合性能的提升。采用涂层拉拔试验,研究不同放电电压、处理距离和处理次数下等离子体射流处理基体表面对修复涂层附着强度的影响。结果表明,随着放电电压的增加,等离子体射流中活性粒子浓度提升,涂层附着强度显著增强,在放电电压值9 kV时提升可达135.14%;处理2次效果最佳,而处理3次后涂层附着强度反而下降;7 mm为最优处理距离。综合最佳处理参数为电压9 kV、处理距离7 mm、2次处理,涂层附着强度平均提升55.53%。射流处理还有效提高了涂层残留面积并改变涂层破坏模式,使界面失效比例下降,内聚失效比例升高。研究了大气压氩等离子体射流对GFRP基体表面的改性机理。通过材料表面分析手段研究不同射流处理条件下材料表面微观物理结构和化学成分的变化。结果表明,等离子体射流处理后样品表面自由能显著提升约30 mN/m,表面C/O比明显下降,含氧极性基团增多。放电电压的增大会显著提升基体表面自由能极性分量,9 kV电压、7 mm距离、2次处理时可提升33.31 mN/m;适当处理次数和处理距离可增强表面极性基团含量并优化表面粗糙度,否则会过度刻蚀削弱改性效果。研究了氩等离子体射流处理对涂层与GFRP基体结合界面耐久性的影响,探索了空气射流等离子体辅助材料表面喷涂修复新方法。在90 ℃、85% RH条件下老化0天、7天和14天后,等离子体组样品涂层附着力分别较对照组提高55.53%、59.89%和76.77%,老化后等离子体组样品的涂层内聚失效比例较对照组增大,且出现基体内聚失效,表明等离子体处理能够有效延缓界面性能的下降。空气射流等离子体辅助喷涂修复工艺在功率40 W、气流2 L/min、进液速度1 mL/min条件下,获得的涂层附着强度较对照组最多可提升14.72%;然而,放电时间过长可能导致树脂降解和金属电极污染,使得修复涂层附着强度较对照组下降超20%。

Wind turbine blades operating in coastal regions of Guangdong are susceptible to surface damage under prolonged exposure to harsh environmental conditions, which significantly undermines their reliability and service life. Conventional repair techniques often result in poor interfacial adhesion between the applied coating and the blade substrate. This study proposes a surface modification approach based on atmospheric-pressure argon plasma jet, investigates the underlying modification mechanisms, and optimizes key processing parameters. A systematic evaluation is conducted on the influence of plasma jet treatment on the interfacial bonding performance between the glass fiber reinforced polymer (GFRP) substrate and the repair coating, thereby exploring a novel repair methodology for wind turbine blades.The atmospheric pressure argon plasma jet surface treatment was used to enhance the interfacial bonding performance between the GFRP substrate and the resin coating. A series of coating pull-off tests were conducted to investigate the influence of discharge voltage, treatment distance, and the number of treatment cycles on the adhesion strength of the repair coating. The results show that as the discharge voltage increased, the concentration of active particles in the plasma jet increased, significantly enhancing the coating adhesion strength, with an improvement of up to 135.14% at 9 kV. The optimal number of treatment cycles was found to be two cycles, whereas a third treatment resulted in reduced adhesion. The optimal treatment distance was 7 mm. The best treatment parameters were a peak-to-peak voltage of 9 kV, a treatment distance of 7 mm, and 2 treatment cycles, resulting in an average increase of 55.53% in coating adhesion strength. Moreover, plasma jet treatment effectively increased the residual coating area after failure and altered the failure mode, reducing the proportion of interfacial failure and increasing the proportion of cohesive failure.The surface modification mechanism of GFRP substrates under atmospheric-pressure argon plasma jet treatment was investigated. Surface characterization techniques were used to investigate changes in the microstructure and chemical composition of the substrate under different plasma jet treatment conditions. The results indicate that the surface free energy of the treated samples increased significantly by approximately 30 mN/m, with a notable decrease in the C/O ratio and an increase in oxygen-containing polar groups. Increasing the discharge voltage significantly enhanced the polar component of surface forces, achieving an increase of 33.31 mN/m at 9 kV, 7 mm, and 2 treatment cycles. Appropriate treatment times and distance could enhance the surface polarity and optimized surface roughness, otherwise, excessive etching would weaken the modification effect.The effects of argon plasma jet treatment on the interfacial durability between the repair coating and the GFRP substrate were investigated, along with an exploration of a air plasma jet assisted surface spraying repair method. Under accelerated aging conditions of 90 °C and 85% relative humidity for 0, 7, and 14 days, the coating adhesion strength of plasma-treated samples increased by 55.53%, 59.89%, and 76.77% respectively compared to the untreated samples. After aging, the plasma-treated samples exhibited a higher proportion of cohesive failure within the coating, and even cohesive failure within the substrate, indicating that plasma treatment effectively delays the degradation of interfacial performance. The air plasma jet-assisted repair process, performed under a discharge power of 40?W, gas flow rate of 2?L/min, and precursor injection rate of 1?mL/min, achieved a maximum enhancement of 14.72% in coating adhesion strength compared to the control group. However, excessive discharge duration led to resin degradation and metal electrode contamination, resulting in a reduction in coating adhesion strength exceeding 20% relative to the control.